Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ
Component — Not a Complete System
This is the indoor unit only. To run, you also need a matching outdoor condenser and a refrigerant line set. Looking for the complete system instead? Browse complete 24,000 BTU systems.
SKU CASSETTE24HP-230B-P
Customize it — compatible add-ons only
Any Olympus multi-zone condenser runs this head — size the total system to your rooms.
Copper pair in 3/8″ × 5/8″ — the diameter this unit's spec sheet calls for. Installed and charged by your HVAC tech.
Clean channel for the lines running down your exterior wall.
Universally compatible tools and care items — maintenance kit, coil cleaner, install tools.
Sizing Help
Not sure if 24K BTU is right for your space?
Proper sizing prevents short-cycling, high bills, and premature failure. Our sizing tool takes 60 seconds.
Resources
Brochures & Manuals
Description
Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ
What's in the Box
Here's what you'll receive with your order
Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceil...
As described
Key Specifications
24000BTU
Cooling Capacity
2000sq ft
Coverage Area
208-230V
Voltage
48.5/46.5/40.5dBA
Noise Level
1
Zone Capacity
Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ — Model Details
What this specific model is sized for, how it installs, how it performs, and what it costs to run.
Room & Space Coverage — 24,000 BTU
The Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ delivers 24,000 BTU of cooling and heating capacity (2-ton class), sized for spaces up to 2,000 sq ft in standard 8-ft ceiling rooms with average insulation. At this capacity the unit handles medium primary rooms, master suites with attached bath, converted garages, and workshops. If your space includes a sunny west-facing wall or a finished bonus room above it, lean toward the upper end of the coverage range.
Power & Electrical Requirements
Power requirement: 208-230V 1-phase 60Hz (standard US residential 240V service). Minimum circuit ampacity is 2.5A with a maximum overcurrent protection of 15A. Wire the outdoor unit with 14 AWG copper on a dedicated 15A double-pole breaker (or single-pole at 120V), with a disconnect within sight of the condenser per NEC 440.14.
Install Difficulty — Professional Install
This is a professionally-installed condenser that requires a licensed HVAC technician with EPA 608 certification. The tech will pull a vacuum on the line set to 500 microns, pressure-test with nitrogen, release the factory charge, and commission per MrCool's startup procedure. Budget 1 full day for install on a single-zone system. Ships with R-410A refrigerant. R-410A is a mature, widely-serviced refrigerant; service technicians and parts are available at any HVAC supply house.
Sound Level & Comfort Features
Operating sound level ranges from 40.5 dB(A) on low to 58.5 dB(A) on high — comparable to typical residential mini-split output. The indoor blower offers 4 fan speeds plus auto mode, letting you trade airflow for quiet operation in bedrooms while running louder in living areas. Quiet mode caps fan speed and compressor rpm for an extra 2–3 dB drop in sound output.
Warranty & Certifications
When you register your unit within 60 days of purchase you get 5-year on parts and 7-year on the compressor through MrCool's registered warranty program. Unregistered coverage drops to None / None — registration takes 3 minutes at mrcool.com and is the highest-ROI post-purchase step you can take. AHRI certified and UL/ETL listed for North American electrical safety — required for most utility rebate and tax credit programs.
What's in the Box & Compatibility
Ships as a Mini Split with remote control included.
Product Details
Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ
Specifications
| Cooling Capacity | 24,000 BTU |
| Heating Capacity | 25,000 BTU |
| Voltage | 208-230 V |
| Refrigerant | R-410A |
| Noise Level | 48.5/46.5/40.5 dBA |
| Coverage Area | 2000 sq ft |
| Zone Capacity | 1 zones |
| Tonnage | 2 Ton |
| Airflow | 683.93/613.30/540.32 CFM |
| Phase | 1 |
| Refrigerant Type | R-410A |
| Liquid Line Size | 3/8 |
| Suction Line Size | 5/8 |
| Country of Origin | China |
Frequently Asked Questions
Everything you need to know about this product
What size room will the Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ cool?
Do I need a licensed HVAC installer?
What electrical circuit do I need for installation?
What warranty do I get?
How fast does HVACZAR ship this unit?
What if it arrives damaged or I change my mind?
What is the warranty on the Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ?
How long does shipping take?
What size room does 24,000 BTU cover?
Do you offer returns?
How can I pay?
Related Products
Ships Nationwide — Shop by State
We deliver the Olympus 2nd Gen 24,000 BTU 2 Ton Ductless Mini-Split Ceiling Cassette with Panel - 230V/60HZ to all 50 states via FedEx, UPS, and truck freight. Each state page lists local rebate programs and utility incentives.

