MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set
Central Ducted·Pro InstallOutdoor Unit Only

MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set

Component — Not a Complete System

This is the outdoor unit only. To run, you also need a matching indoor air handler and a refrigerant line set. Looking for the complete system instead? Browse complete 18,000 BTU systems.

SKU CENTRAL-18-HP-C-230-25

18,000 BTUup to 900 sq ft22 SEER2208-230R-410A
$1,387.00
Pay over time withAffirmaffirmKlarnaKlarna— see your options at checkout.
In Stock — Ships within 1-3 days

Customize it — compatible add-ons only

Same-capacity Central Ducted air handler this condenser is rated with — required to run.

Heat strips made for the MRCOOL Central Ducted air handler — sized in kW by your installer.

MRCOOL 24V smart thermostat for ducted systems — Wi-Fi control and scheduling.

Maintenance kit and coil cleaner keep efficiency (and the warranty) healthy.

Universally compatible tools and care items — maintenance kit, coil cleaner, install tools.

10 years parts and labor warranty · Covers up to 900 sq ft
Ships nationwide · exact freight at checkout · Ships in 1-3 business days
30-day returns on unopened products · See policy
Secure checkout:Visa · Mastercard · Amex · Discover

Sizing Help

Not sure if 18K BTU is right for your space?

Proper sizing prevents short-cycling, high bills, and premature failure. Our sizing tool takes 60 seconds.

Description

MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set

What's in the Box

Here's what you'll receive with your order

Outdoor Condenser Unit

Heat pump condenser with Gold Fin anti-corrosion coating

Installation Hardware

Mounting brackets and hardware kit

Owner Manual

Installation and operation guide

2 Years compressor warranty
R-410A refrigerant
Compressor: 2 Years warrantyParts: 1 Year warranty

Key Specifications

18000BTU

Cooling Capacity

208-230V

Voltage

1

Zone Capacity

18000BTU

Heating Capacity

MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set — Model Details

What this specific model is sized for, how it installs, how it performs, and what it costs to run.

Room & Space Coverage — 18,000 BTU

The MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set delivers 18,000 BTU of cooling and heating capacity, sized for spaces up to 900 sq ft in standard 8-ft ceiling rooms with average insulation. At this capacity the unit handles medium primary rooms, master suites with attached bath, converted garages, and workshops. If your space includes a sunny west-facing wall or a finished bonus room above it, lean toward the upper end of the coverage range.

Efficiency & Operating Cost

This unit is rated at 22 SEER2. SEER2 measures seasonal cooling efficiency — higher is better — and 22 puts this in the premium efficiency tier. Running the unit 8 hours a day at full load draws roughly 196 kWh/month — about $31/month at the US average $0.16/kWh residential rate. Real-world draw is usually 30–50% lower because inverter compressors modulate down most of the time.

Cold & Hot Weather Operating Range

This system produces rated heating capacity down to -1375.2°F ambient, putting it in hyper-heat territory suitable for northern climates where ducted gas is the usual backup. On the cooling side the compressor runs down to -13122°F outdoor ambient, useful for server rooms, grow rooms, and any space that needs year-round cooling.

Power & Electrical Requirements

Power requirement: 208-230V 1-phase 60Hz (standard US residential 240V service). Minimum circuit ampacity is 18A with a maximum overcurrent protection of 30A. Wire the outdoor unit with 10 AWG copper on a dedicated 30A double-pole breaker (or single-pole at 120V), with a disconnect within sight of the condenser per NEC 440.14.

Install Difficulty — Professional Install

This is a professionally-installed condenser that requires a licensed HVAC technician with EPA 608 certification. The tech will pull a vacuum on the line set to 500 microns, pressure-test with nitrogen, release the factory charge, and commission per MrCool's startup procedure. Budget 1 full day for install on a single-zone system. A 25ft line set is included in the box — sufficient for most indoor-to-outdoor runs where the condenser sits on a ground pad directly outside the serviced room. Ships with R-410A refrigerant. R-410A is a mature, widely-serviced refrigerant; service technicians and parts are available at any HVAC supply house.

Product Details

MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set

Specifications

Cooling Capacity18,000 BTU
Heating Capacity18,000 BTU
SEER2 Rating22
Voltage208-230 V
RefrigerantR-410A
Zone Capacity1 zones
SEER Rating22
Phase1
Refrigerant TypeR-410A
Refrigerant Charge56.44 oz
Liquid Line Size1/4
Suction Line Size1/2

Features

  • Includes features such as timer mode, auto cool mode, fan only mode, and more
  • Wired thermostat included (.78 in x 4.72 in x 4.72in)
  • Multi position installation
  • Optional heating kit avaible
  • R-410A environmentally friendly refrigerant
  • 10 year parts and labor warranty*

Frequently Asked Questions

Everything you need to know about this product

What size room will the MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set cool?

At 18,000 BTU this unit is sized for rooms up to 900 sq ft under standard 8-ft ceilings with average insulation. Add 10–20% for sun-exposed rooms, poorly insulated spaces, or ceilings above 9 ft.

Do I need a licensed HVAC installer?

Yes — this unit is professionally-installed. The installer needs EPA 608 certification to handle R-410A, plus standard HVAC tools (vacuum pump, manifold gauges, nitrogen kit). Expect a one-day install on a single-zone system, more on multi-zone.

Is this unit eligible for the federal 25C tax credit?

At 22 SEER2 this unit meets the efficiency thresholds most ENERGY STAR cold-climate heat pump programs require, which is the trigger for the 25C credit (up to 30% / $2,000 in 2026). Confirm with your tax advisor and save the AHRI certificate from your order confirmation.

How cold can it get outside before this heat pump stops heating?

Rated heating capacity holds down to -1375.2°F. Below that temperature most units continue running but deliver reduced output. Hyper-heat units like this one are designed for northern climates with no supplementary heat.

What electrical circuit do I need for installation?

208-230V dedicated circuit with the disconnect within sight of the outdoor unit per NEC 440.14. An electrician will size the breaker based on the minimum circuit ampacity shown on the nameplate. Budget $400–$900 for a new dedicated 240V circuit if one isn't already present.

How fast does HVACZAR ship this unit?

Shipping is calculated at checkout from the order weight, and you see the exact charge before paying. In-stock SKUs leave the warehouse within 1–3 business days. Transit time is 3–7 business days via truck freight (with liftgate delivery) for outdoor units and UPS Ground for accessories. Tracking is emailed at pickup.

What if it arrives damaged or I change my mind?

Inspect the unit before signing for freight delivery. If there is visible damage, note it on the delivery receipt and refuse the shipment — we ship a replacement at no cost. Unopened and unused units can be returned within 30 days for a refund less outbound shipping.

What is the warranty on the MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set?

The MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set comes with a 10 years parts and labor manufacturer warranty when purchased from HVACZAR, an authorized MrCool dealer. Register your unit after purchase to activate full warranty coverage.

How long does shipping take?

Shipping is calculated at checkout from the order weight. Most MrCool systems ship within 1-3 business days and arrive in 3-7 business days via FedEx, UPS, or truck freight with liftgate delivery.

What size room does 18,000 BTU cover?

A 18,000 BTU unit is sized for rooms up to 900 sq ft. Proper sizing depends on ceiling height, insulation, climate zone, and window exposure. Use our system finder for a precise recommendation.

What is the efficiency rating?

This system is rated at 22 SEER2, meeting or exceeding Energy Star efficiency standards. Higher SEER2 ratings mean lower electric bills and better cooling efficiency.

Do you offer returns?

Yes. HVACZAR offers a 30-day return policy on unopened, unused products in original packaging. Contact us to initiate a return and receive a return authorization number.

How can I pay?

We accept all major credit cards (Visa, Mastercard, American Express, Discover) via Stripe secure checkout. All transactions are encrypted and protected.

Ships Nationwide — Shop by State

We deliver the MRCOOL 18k BTU 19.2 SEER Condenser - 25 foot MRCOOL Pre-Charged Line Set to all 50 states via FedEx, UPS, and truck freight. Each state page lists local rebate programs and utility incentives.

View all 50 states →